dc:titleThe intensity of subacute local biological effects after the implantation of ALBO-OS dental material based on hydroxyapatite and poly(lactide-co-glycolide): in vivo evaluation in rats
dc:creatorVeljko, Ilić
dc:creatorBiočanin, Vladimir
dc:creatorĐorđe, Antonijević
dc:creatorBožana, Petrović
dc:creatorVukoman, Jokanović
dc:creatorDragan, Ilić
dc:creatorVesna, Danilović
dc:creatorNina, Japundžić-Žigon
dc:creatorSmiljana, Paraš
dc:creatorMilutinović, Jovana
dc:creatorSanja, Milutinović-Smiljanić
dc:subjecthydroxyapatite
dc:subjectpoly(lactic-co-glycolic acid)
dc:subjectbone substitutes
dc:subjectosseointegration
dc:subjectbiocompatibility
dc:subjectinflammation
dc:subjectBio-Oss
dc:subjecttibial defect
dc:subjectsubcutaneous implantation
dc:subjecthistomorphometry
dc:descriptionAbstract Objectives This study aimed to evaluate the intensity of the subacute local biological effects after implantation and osseoconductive potential of novel hydroxyapatite-based bone substitute coated with poly (lactide-co-glycolide), named ALBO-OS, in comparison to Bio-Oss®. Methods Fifteen male Wistar rats, randomly assigned into groups: 10, 20, and 30 days (n꞊5), were subcutaneously implanted with ALBO-OS and Bio-Oss®. Furthermore, artificially made bone defects on both rat’s tibias were implanted with experimental materials. Unimplanted defects represented negative control. After the animals’ euthanizing, tissue samples were prepared and analyzed histologically and histomorphometrically. Results Normal healing of the epithelial tissue was observed, with no signs of infection or necrosis. Minimal vascular congestion was noted immediately around the graft, with no signs of tissue oedema, with a minimal capsule thickness. The applied material did not cause an inflammatory response (IR) of significant intensity, and 20 days after implantation, the IR was mainly assessed as minimal. The tibial specimen showed that ALBO-OS has good osseoconductive potential, similar to Bio-Oss®, as well as low levels of acute and subacute inflammation. Conclusions The tested material exhibits satisfying biocompatibility, similar to Bio-Oss®.
dc:publisherDe Gruyter
dc:date2024
dc:typeinfo:eu-repo/semantics/article
dc:typeinfo:eu-repo/semantics/publishedVersion
dc:identifierhttps://stomatoloskifakultet.rs/nauka/publikacija/780
dc:identifierDOI 10.1515/bmt-2023-0640
dc:identifierISSN 0013-5585
dc:sourceBiomedical Engineering / Biomedizinische Technik 69(6): 563-574
dc:languageen
dc:rightsinfo:eu-repo/semantics/closedAccess
dc:rightsSva prava zadržana